Skip to main content
GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System

GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Better meeting your needs by better understanding them.  Six key considerations to help you deliver optimal results.

Angulation Hemodynamics Repositioning Sizing Conformability Support

Unique angulation control, available at the intermediate stage and again after full deployment, promotes 360° wall apposition.

 

Continuous blood flow promotes hemodynamic stability throughout the procedure, which minimizes “windsocking.”

Thumbnail of Hemodynamic Flow
NO rapid pacing used in 93% of cases1

 

During intermediate deployment stage, correct for imaging parallax and refine placement as needed.

97% technical success1

 

Unique 6–33% oversizing window allows you to choose the optimal radial force to fit anatomy and etiology.

 

Control, along with the exceptional conformability of the stent graft itself, helps minimize the risk of endoleaks.

Dr. Austermann Live Case #2 - Conformable GORE® TAG® Thoracic Stent Graft with ACTIVE CONTROL System
Real world2 treatment* transection zero Type III endoleaks†, ruptures, device fractures, compressions, conversions

  

Aortic Ally FSA stories from the field

Support you can count on   

  • 8+ years  –  Average field representatives’ tenure supporting Gore’s aortic devices, building on diverse clinical backgrounds
  • Non-commissioned sales force – our focus is on outcomes
  • Training needs – Essential technical support with a deep reservoir of product knowledge
  • From pre-case planning to procedural consultation we are by your side to provide support

Contact your Gore representative:

Email MPDTempeSalesSupport@wlgore.com

Call 800-469-6999, or Request contact

* GORE® TAG® Conformable Device.
† Endoleak requiring intervention. No endoleaks persisted past one month or required intervention.

  1. W. L. Gore & Associates.  Observational Registry Characterizing the Performance and Feature Use of the GORE® TAG® Conformable Thoracic Stent Graft Featuring ACTIVE CONTROL System.  NLM Identifier: NCT03286400.  Published September 18, 2017.  Updated December 17, 2020. Accessed February 23, 2021.   Available from: https://clinicaltrials.gov/ct2/show/NCT03286400