Skip to main content

Catalogue Numbers for GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface - Canada

GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface

Indicated for Use in the endovascular grafting of peripheral arteries
(5-8mm diameters with radiopaque markers)

0.014/0.018" (PAJR) or 0.035" (PAH) Guidewire

Catalogue Number Endoprosthesis Labeled Diameter* (mm) Endoprosthesis Length* (cm) Catheter Length** (cm) Recommended Vessel Diameter (mm) Device Profile (Fr) Recommended Balloon Diameter for Device Touch-Up (mm)
PAJR050202B 5 2.5 120 4.0 – 4.7 6 5
PAJR050502B 5 5.0 120 4.0 – 4.7 6 5
PAJR051002B 5 10.0 120 4.0 – 4.7 6 5
PAJR051502B 5 15.0 120 4.0 – 4.7 6 5
PAJR052502B 5 25.0 120 4.0 – 4.7 6 5
PAJR060202B 6 2.5 120 4.8 – 5.5 6 6
PAJR060502B 6 5.0 120 4.8 – 5.5 6 6
PAJR061002B 6 10.0 120 4.8 – 5.5 6 6
PAJR061502B 6 15.0 120 4.8 – 5.5 6 6
PAJR062502B 6 25.0 120 4.8 – 5.5 6 6
PAJR070202B 7 2.5 120 5.6 – 6.5 7 7
PAJR070502B 7 5.0 120 5.6 – 6.5 7 7
PAJR071002B 7 10.0 120 5.6 – 6.5 7 7
PAJR071502B 7 15.0 120 5.6 – 6.5 7 7
PAJR072502B 7 25.0 120 5.6 – 6.5 7 7
PAJR080202B 8 2.5 120 6.6 – 7.5 7 8
PAJR080502B 8 5.0 120 6.6 – 7.5 7 8
PAJR081002B 8 10.0 120 6.6 – 7.5 7 8
PAJR081502B 8 15.0 120 6.6 – 7.5 7 8
PAJR082502B 8 25.0 120 6.6 – 7.5 7 8
PAH090502B 9 5.0 120 7.6 – 8.5 9 9
PAH091002B 9 10.0 120 7.6 – 8.5 9 9
PAH091502B 9 15.0 120 7.6 – 8.5 9 9
PAH100502B 10 5.0 120 8.6 – 9.5 11 10
PAH101002B 10 10.0 120 8.6 – 9.5 11 10
PAH101502B 10 15.0 120 8.6 – 9.5 11 10
PAH110502B 11 5.0 120 9.6 – 10.5 11 12
PAH111002B 11 10.0 120 9.6 – 10.5 11 12
PAH130502B 13 5.0 120 10.6 – 12.0 12 14
PAH131002B 13 10.0 120 10.6 – 12.0 12 14

Catalogue numbers starting with PAJR indicate low profile items.

* Labeled device diameters and lengths are nominal.

** Ensure the guidewire is the appropriate size (see Instructions for Use) and has a length at least twice that of the delivery catheter.

Recommended endoprosthesis compression within the vessel is approximately 5 - 20%.

The 10 mm diameter device is compatible with the following 10 Fr introducer sheaths: Cordis AVANTI® Sheath Introducer, Boston Scientific SUPER SHEATH® Introducer Sheath, B. Braun INTRADYN Tear-Away Introducer Sheath.

INTENDED USE / INDICATIONS: The GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface is a flexible, self-expanding endoluminal prosthesis for endovascular grafting of peripheral arteries.
CONTRAINDICATIONS: Non-compliant lesions where full expansion of an angioplasty balloon catheter was not achieved during pre-dilatation, or where lesions cannot be dilated sufficiently to allow passage of the delivery system. Do not use the GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Surface in patients with known hypersensitivity to heparin, including those patients who have had a previous incidence of Heparin-Induced Thrombocytopenia (HIT) type II. Refer to Instructions for Use at goremedical.com for a complete description of all contraindications, warnings, precautions and adverse events. Rx Only