Skip to main content

The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is not authorized for use with thoracoabdominal and pararenal branched devices indicated with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis as a branch component in Canada.

Catalogue Numbers for GORE® VIABAHN® VBX Balloon Expandable 
Endoprosthesis - U.S. 

VBX Stent Graft 
Catalogue Number 
Reduced Profile 
VBX Stent Graft 
Catalogue Number 
Stent 
Labeled/Nominal 
Diameter (mm) 
Maximum 
Post-Dilated Stent 
Diameter (mm)a

Stent 

Length (mm) 

Catheter 

Length (cm) 

Guidewire 

Diameter (in) 

Reduced Profile 
VBX Stent Graft Introducer 
Sheath Size (Fr) 
BXA051501A 
BXB051501A 
5
8
15
80
.035
6
BXA051901A 
BXB051901A 
5
8
19
80
.035
6
BXA052901A 
BXB052901A 
5
8
29
80
.035
6
BXA053901A 
BXB053901A 
5
8
39
80
.035
6
BXA055901A 
BXB055901A 
5
8
59
80
.035
6
BXA057901A 
BXB057901A 
5
8
79
80
.035
6
BXA061501A 
BXB061501A 
6
8
15
80
.035
6
BXA061901A 
BXB061901A 
6
8
19
80
.035
6
BXA062901A 
BXB062901A 
6
8
29
80
.035
6
BXA063901A 
BXB063901A 
6
8
39
80
.035
6
BXA065901A 
BXB065901A 
6
8
59
80
.035
6
BXA067901A 
BXB067901A 
6
8
79
80
.035
6
BXA071501A 
BXB071501A 
7
11
15
80
.035
6
BXA071901A 
BXB071901A 
7
11
19
80
.035
6
BXA072901A 
BXB072901A 
7
11
29
80
.035
6
BXA073901A 
BXB073901A 
7
11
39
80
.035
6
BXA075901A 
BXB075901A 
7
11
59
80
.035
6
BXA077901A 
BXB077901A 
7
11
79
80
.035
6
BXA082901A 
BXB082901A 
8
11
29
80
.035
7
BXA083901A 
BXB083901A 
8
11
39
80
.035
7
BXA085901A 
BXB085901A 
8
11
59
80
.035
7
BXA087901A 
BXB087901A 
8
11
79
80
.035
7
BXA092901A 
BXB092901A 
9
13
29
80
.035
7
BXA093901A 
BXB093901A 
9
13
39
80
.035
7
BXA095901A 
BXB095901A 
9
13
59
80
.035
7
BXA097901A 
BXB097901A 
9
13
79
80
.035
7
BXA102901A 
BXB102901A 
10
13
29
80
.035
7
BXA103901A 
BXB103901A
10
13
39
80
.035
7
BXA105901A 
BXB105901A
10
13
59
80
.035
7
BXA107901A 
BXB107901A
10
13
79
80
.035
7
BXA112901A 
BXB112901A
11
16b 
29
80
.035
8
BXA113901A 
BXB113901A
11
16b 
39
80
.035
8
BXA115901A 
BXB115901A
11
16b 
59
80
.035
8
BXA117901A 
BXB117901A
11
16b 
79
80
.035
8
BXAL082901A 
BXBL082901A 
8
16b 
29
80
.035
7
BXAL083901A 
BXBL083901A 
8
16b 
39
80
.035
7
BXAL085901A 
BXBL085901A 
8
16b 
59
80
.035
8
BXAL087901A 
BXBL087901A 
8
16b 
79
80
.035
8
BXA051502A 
BXB051502A 
5
8
15
135
.035
6
BXA051902A 
BXB051902A 
5
8
19
135
.035
6
BXA052902A 
BXB052902A 
5
8
29
135
.035
6
BXA053902A 
BXB053902A 
5
8
39
135
.035
6
BXA055902A 
BXB055902A 
5
8
59
135
.035
6
BXA057902A 
BXB057902A 
5
8
79
135
.035
6
BXA061502A 
BXB061502A 
6
8
15
135
.035
6
BXA061902A 
BXB061902A 
6
8
19
135
.035
6
BXA062902A 
BXB062902A 
6
8
29
135
.035
6
BXA063902A 
BXB063902A 
6
8
39
135
.035
6
BXA065902A 
BXB065902A 
6
8
59
135
.035
6
BXA067902A 
BXB067902A 
6
8
79
135
.035
6
BXA071502A 
BXB071502A 
7
11
15
135
.035
6
BXA071902A 
BXB071902A 
7
11
19
135
.035
6
BXA072902A 
BXB072902A 
7
11
29
135
.035
6
BXA073902A 
BXB073902A 
7
11
39
135
.035
6
BXA075902A 
BXB075902A 
7
11
59
135
.035
6
BXA077902A 
BXB077902A 
7
11
79
135
.035
6
BXA082902A 
BXB082902A 
8
11
29
135
.035
7
BXA083902A 
BXB083902A 
8
11
39
135
.035
7
BXA085902A 
BXB085902A 
8
11
59
135
.035
7
BXA087902A 
BXB087902A 
8
11
79
135
.035
7
BXA092902A 
BXB092902A 
9
13
29
135
.035
7
BXA093902A 
BXB093902A 
9
13
39
135
.035
7
BXA095902A 
BXB095902A 
9
13
59
135
.035
7
BXA097902A 
BXB097902A 
9
13
79
135
.035
7
BXA102902A 
BXB102902A 
10
13
29
135
.035
7
BXA103902A 
BXB103902A
10
13
39
135
.035
7
BXA105902A 
BXB105902A
10
13
59
135
.035
7
BXA107902A 
BXB107902A
10
13
79
135
.035
7
BXA112902A 
BXB112902A
11
16b 
29
135
.035
8
BXA113902A 
BXB113902A
11
16b 
39
135
.035
8
BXA115902A 
BXB115902A
11
16b 
59
135
.035
8
BXA117902A 
BXB117902A
11
16b 
79
135
.035
8
BXAL082902A 
BXBL082902A 
8
16b 
29
135
.035
7
BXAL083902A 
BXBL083902A 
8
16b 
39
135
.035
7
BXAL085902A 
BXBL085902A 
8
16b 
59
135
.035
8
BXAL087902A 
BXBL087902A 
8
16b 
79
135
.035
8

a Secondary balloon required to post-dilate the stent beyond its nominal deployed diameter (secondary balloon not included). 
b Technical limit of the device as determined by in vitro testing for the indicated use; device expansion beyond 13 mm was not studied as part of the Gore VBX FLEX Clinical Study. See Instructions for Use.

Catalogue Numbers for GORE® VIABAHN® VBX Balloon Expandable 
Endoprosthesis - Canada

VBX Stent Graft 
Catalogue Number 
Reduced Profile 
VBX Stent Graft 
Catalogue Number 
Stent 
Labeled/Nominal 
Diameter (mm) 
Maximum 
Post-Dilated Stent 
Diameter (mm)a,b

Stent 

Length (mm)b

Catheter 

Length (cm) 

Guidewire 

Diameter (in) 

Reduced Profile 
VBX Stent Graft Introducer 
Sheath Size (Fr)  
BXA051502B
BXB051502B
5
8
15

135

.035
6
BXA051902B
BXB051902B
5
8
19

135

.035
6
BXA052902B
BXB052902B
5
8
29

135

.035
6
BXA053902B
BXB053902B
5
8
39

135

.035
6
BXA055902B
BXB055902B
5
8
59

135

.035
6
BXA057902B
BXB057902B
5
8
79

135

.035
6
BXA061502B
BXB061502B
6
8
15

135

.035
6
BXA061902B
BXB061902B
6
8
19

135

.035
6
BXA062902B
BXB062902B
6
8
29

135

.035
6
BXA063902B
BXB063902B
6
8
39

135

.035
6
BXA065902B
BXB065902B
6
8
59

135

.035
6
BXA067902B
BXB067902B
6
8
79

135

.035
6
BXA071502B
BXB071502B
7
11
15

135

.035
6
BXA071902B
BXB071902B
7
11
19

135

.035
6
BXA072902B
BXB072902B
7
11
29

135

.035
6
BXA073902B
BXB073902B
7
11
39

135

.035
6
BXA075902B
BXB075902B
7
11
59

135

.035
6
BXA077902B
BXB077902B
7
11
79

135

.035
6
BXA082902B
BXB082902B
8
11
29

135

.035
7
BXA083902B
BXB083902B
8
11
39

135

.035
7
BXA085902B
BXB085902B
8
11
59

135

.035
7
BXA087902B
BXB087902B
8
11
79

135

.035
7
BXA092902B
BXB092902B
9
13
29

135

.035
7
BXA093902B
BXB093902B
9
13
39

135

.035
7
BXA095902B
BXB095902B
9
13
59

135

.035
7
BXA097902B
BXB097902B
9
13
79

135

.035
7
BXA102902B
Unchanged
10
13
29

135

.035
8
BXA103902B
Unchanged
10
13
39

135

.035
8
BXA105902B
Unchanged
10
13
59

135

.035
8
BXA107902B
Unchanged
10
13
79

135

.035
8
BXA112902B
Unchanged
11
16
29

135

.035
8
BXA113902B
Unchanged
11
16
39

135

.035
8
BXA115902B
Unchanged
11
16
59

135

.035
8
BXA117902B
Unchanged
11
16
79

135

.035
8
BXAL082902B
BXBL082902B
8
16
29

135

.035
7
BXAL083902B
BXBL083902B
8
16
39

135

.035
7
BXAL085902B
BXBL085902B
8
16
59

135

.035
8
BXAL087902B
BXBL087902B
8
16
79

135

.035
8

a Secondary balloon required to post-dilate the stent beyond its nominal deployed diameter (secondary balloon not included). 
b Based on idealized in-vitro conditions and provided to be used as a general guide.


IFU Consult instructions

Refer to Instructions for Use at eifu.goremedical.com for a complete description of all applicable indications, warnings, precautions and contraindications for the markets where this product is available. RXOnly

INDICATIONS FOR USE IN THE US: The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is indicated for the treatment of de novo or restenotic lesions found in iliac arteries with reference vessel diameters ranging from 5 mm - 13 mm and lesion lengths up to 110 mm, including lesions at the aortic bifurcation. The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is indicated to maintain visceral artery perfusion as a bridging stent in:

  • fenestrated endovascular aortic aneurysm repair with 6-8 mm diameter fenestrations
  • branched endovascular aortic aneurysm repair with 6-8 mm diameter branches (e.g. portals, cuffs, or directional branches) that are at least 10 mm in length

Bridging stent use is limited to aortic endovascular graft systems wherein safety and effectiveness has been demonstrated.

CONTRAINDICATIONS: Do not use the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis in patients with known hypersensitivity to heparin, including those patients who have had a previous incident of Heparin-Induced Thrombocytopenia (HIT) type II. Patients with known sensitivities or allergies to the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis materials including expanded polytetrafluoroethylene (ePTFE), fluorinated ethylene propylene (FEP), stainless steel, and heparin. 

The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is not authorized for use with thoracoabdominal and pararenal branched devices indicated with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis as a branch component in Canada.