Catalogue numbers for GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis

The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is not authorized for use with thoracoabdominal and pararenal branched devices indicated with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis as a branch component in Canada.
Catalogue Numbers for GORE® VIABAHN® VBX Balloon Expandable | |||||||
|---|---|---|---|---|---|---|---|
| VBX Stent Graft Catalogue Number | Reduced Profile VBX Stent Graft Catalogue Number | Stent Labeled/Nominal Diameter (mm) | Maximum Post-Dilated Stent Diameter (mm)a | Stent Length (mm) | Catheter Length (cm) | Guidewire Diameter (in) | Reduced Profile VBX Stent Graft Introducer Sheath Size (Fr) |
BXA051501A | BXB051501A | 5 | 8 | 15 | 80 | .035 | 6 |
BXA051901A | BXB051901A | 5 | 8 | 19 | 80 | .035 | 6 |
BXA052901A | BXB052901A | 5 | 8 | 29 | 80 | .035 | 6 |
BXA053901A | BXB053901A | 5 | 8 | 39 | 80 | .035 | 6 |
BXA055901A | BXB055901A | 5 | 8 | 59 | 80 | .035 | 6 |
BXA057901A | BXB057901A | 5 | 8 | 79 | 80 | .035 | 6 |
BXA061501A | BXB061501A | 6 | 8 | 15 | 80 | .035 | 6 |
BXA061901A | BXB061901A | 6 | 8 | 19 | 80 | .035 | 6 |
BXA062901A | BXB062901A | 6 | 8 | 29 | 80 | .035 | 6 |
BXA063901A | BXB063901A | 6 | 8 | 39 | 80 | .035 | 6 |
BXA065901A | BXB065901A | 6 | 8 | 59 | 80 | .035 | 6 |
BXA067901A | BXB067901A | 6 | 8 | 79 | 80 | .035 | 6 |
BXA071501A | BXB071501A | 7 | 11 | 15 | 80 | .035 | 6 |
BXA071901A | BXB071901A | 7 | 11 | 19 | 80 | .035 | 6 |
BXA072901A | BXB072901A | 7 | 11 | 29 | 80 | .035 | 6 |
BXA073901A | BXB073901A | 7 | 11 | 39 | 80 | .035 | 6 |
BXA075901A | BXB075901A | 7 | 11 | 59 | 80 | .035 | 6 |
BXA077901A | BXB077901A | 7 | 11 | 79 | 80 | .035 | 6 |
BXA082901A | BXB082901A | 8 | 11 | 29 | 80 | .035 | 7 |
BXA083901A | BXB083901A | 8 | 11 | 39 | 80 | .035 | 7 |
BXA085901A | BXB085901A | 8 | 11 | 59 | 80 | .035 | 7 |
BXA087901A | BXB087901A | 8 | 11 | 79 | 80 | .035 | 7 |
BXA092901A | BXB092901A | 9 | 13 | 29 | 80 | .035 | 7 |
BXA093901A | BXB093901A | 9 | 13 | 39 | 80 | .035 | 7 |
BXA095901A | BXB095901A | 9 | 13 | 59 | 80 | .035 | 7 |
BXA097901A | BXB097901A | 9 | 13 | 79 | 80 | .035 | 7 |
BXA102901A | BXB102901A | 10 | 13 | 29 | 80 | .035 | 7 |
BXA103901A | BXB103901A | 10 | 13 | 39 | 80 | .035 | 7 |
BXA105901A | BXB105901A | 10 | 13 | 59 | 80 | .035 | 7 |
BXA107901A | BXB107901A | 10 | 13 | 79 | 80 | .035 | 7 |
BXA112901A | BXB112901A | 11 | 16b | 29 | 80 | .035 | 8 |
BXA113901A | BXB113901A | 11 | 16b | 39 | 80 | .035 | 8 |
BXA115901A | BXB115901A | 11 | 16b | 59 | 80 | .035 | 8 |
BXA117901A | BXB117901A | 11 | 16b | 79 | 80 | .035 | 8 |
BXAL082901A | BXBL082901A | 8 | 16b | 29 | 80 | .035 | 7 |
BXAL083901A | BXBL083901A | 8 | 16b | 39 | 80 | .035 | 7 |
BXAL085901A | BXBL085901A | 8 | 16b | 59 | 80 | .035 | 8 |
BXAL087901A | BXBL087901A | 8 | 16b | 79 | 80 | .035 | 8 |
BXA051502A | BXB051502A | 5 | 8 | 15 | 135 | .035 | 6 |
BXA051902A | BXB051902A | 5 | 8 | 19 | 135 | .035 | 6 |
BXA052902A | BXB052902A | 5 | 8 | 29 | 135 | .035 | 6 |
BXA053902A | BXB053902A | 5 | 8 | 39 | 135 | .035 | 6 |
BXA055902A | BXB055902A | 5 | 8 | 59 | 135 | .035 | 6 |
BXA057902A | BXB057902A | 5 | 8 | 79 | 135 | .035 | 6 |
BXA061502A | BXB061502A | 6 | 8 | 15 | 135 | .035 | 6 |
BXA061902A | BXB061902A | 6 | 8 | 19 | 135 | .035 | 6 |
BXA062902A | BXB062902A | 6 | 8 | 29 | 135 | .035 | 6 |
BXA063902A | BXB063902A | 6 | 8 | 39 | 135 | .035 | 6 |
BXA065902A | BXB065902A | 6 | 8 | 59 | 135 | .035 | 6 |
BXA067902A | BXB067902A | 6 | 8 | 79 | 135 | .035 | 6 |
BXA071502A | BXB071502A | 7 | 11 | 15 | 135 | .035 | 6 |
BXA071902A | BXB071902A | 7 | 11 | 19 | 135 | .035 | 6 |
BXA072902A | BXB072902A | 7 | 11 | 29 | 135 | .035 | 6 |
BXA073902A | BXB073902A | 7 | 11 | 39 | 135 | .035 | 6 |
BXA075902A | BXB075902A | 7 | 11 | 59 | 135 | .035 | 6 |
BXA077902A | BXB077902A | 7 | 11 | 79 | 135 | .035 | 6 |
BXA082902A | BXB082902A | 8 | 11 | 29 | 135 | .035 | 7 |
BXA083902A | BXB083902A | 8 | 11 | 39 | 135 | .035 | 7 |
BXA085902A | BXB085902A | 8 | 11 | 59 | 135 | .035 | 7 |
BXA087902A | BXB087902A | 8 | 11 | 79 | 135 | .035 | 7 |
BXA092902A | BXB092902A | 9 | 13 | 29 | 135 | .035 | 7 |
BXA093902A | BXB093902A | 9 | 13 | 39 | 135 | .035 | 7 |
BXA095902A | BXB095902A | 9 | 13 | 59 | 135 | .035 | 7 |
BXA097902A | BXB097902A | 9 | 13 | 79 | 135 | .035 | 7 |
BXA102902A | BXB102902A | 10 | 13 | 29 | 135 | .035 | 7 |
BXA103902A | BXB103902A | 10 | 13 | 39 | 135 | .035 | 7 |
BXA105902A | BXB105902A | 10 | 13 | 59 | 135 | .035 | 7 |
BXA107902A | BXB107902A | 10 | 13 | 79 | 135 | .035 | 7 |
BXA112902A | BXB112902A | 11 | 16b | 29 | 135 | .035 | 8 |
BXA113902A | BXB113902A | 11 | 16b | 39 | 135 | .035 | 8 |
BXA115902A | BXB115902A | 11 | 16b | 59 | 135 | .035 | 8 |
BXA117902A | BXB117902A | 11 | 16b | 79 | 135 | .035 | 8 |
BXAL082902A | BXBL082902A | 8 | 16b | 29 | 135 | .035 | 7 |
BXAL083902A | BXBL083902A | 8 | 16b | 39 | 135 | .035 | 7 |
BXAL085902A | BXBL085902A | 8 | 16b | 59 | 135 | .035 | 8 |
BXAL087902A | BXBL087902A | 8 | 16b | 79 | 135 | .035 | 8 |
a Secondary balloon required to post-dilate the stent beyond its nominal deployed diameter (secondary balloon not included).
b Technical limit of the device as determined by in vitro testing for the indicated use; device expansion beyond 13 mm was not studied as part of the Gore VBX FLEX Clinical Study. See Instructions for Use.
Catalogue Numbers for GORE® VIABAHN® VBX Balloon Expandable | |||||||
|---|---|---|---|---|---|---|---|
| VBX Stent Graft Catalogue Number | Reduced Profile VBX Stent Graft Catalogue Number | Stent Labeled/Nominal Diameter (mm) | Maximum Post-Dilated Stent Diameter (mm)a,b | Stent Length (mm)b | Catheter Length (cm) | Guidewire Diameter (in) | Reduced Profile VBX Stent Graft Introducer Sheath Size (Fr) |
BXA051502B | BXB051502B | 5 | 8 | 15 | 135 | .035 | 6 |
BXA051902B | BXB051902B | 5 | 8 | 19 | 135 | .035 | 6 |
BXA052902B | BXB052902B | 5 | 8 | 29 | 135 | .035 | 6 |
BXA053902B | BXB053902B | 5 | 8 | 39 | 135 | .035 | 6 |
BXA055902B | BXB055902B | 5 | 8 | 59 | 135 | .035 | 6 |
BXA057902B | BXB057902B | 5 | 8 | 79 | 135 | .035 | 6 |
BXA061502B | BXB061502B | 6 | 8 | 15 | 135 | .035 | 6 |
BXA061902B | BXB061902B | 6 | 8 | 19 | 135 | .035 | 6 |
BXA062902B | BXB062902B | 6 | 8 | 29 | 135 | .035 | 6 |
BXA063902B | BXB063902B | 6 | 8 | 39 | 135 | .035 | 6 |
BXA065902B | BXB065902B | 6 | 8 | 59 | 135 | .035 | 6 |
BXA067902B | BXB067902B | 6 | 8 | 79 | 135 | .035 | 6 |
BXA071502B | BXB071502B | 7 | 11 | 15 | 135 | .035 | 6 |
BXA071902B | BXB071902B | 7 | 11 | 19 | 135 | .035 | 6 |
BXA072902B | BXB072902B | 7 | 11 | 29 | 135 | .035 | 6 |
BXA073902B | BXB073902B | 7 | 11 | 39 | 135 | .035 | 6 |
BXA075902B | BXB075902B | 7 | 11 | 59 | 135 | .035 | 6 |
BXA077902B | BXB077902B | 7 | 11 | 79 | 135 | .035 | 6 |
BXA082902B | BXB082902B | 8 | 11 | 29 | 135 | .035 | 7 |
BXA083902B | BXB083902B | 8 | 11 | 39 | 135 | .035 | 7 |
BXA085902B | BXB085902B | 8 | 11 | 59 | 135 | .035 | 7 |
BXA087902B | BXB087902B | 8 | 11 | 79 | 135 | .035 | 7 |
BXA092902B | BXB092902B | 9 | 13 | 29 | 135 | .035 | 7 |
BXA093902B | BXB093902B | 9 | 13 | 39 | 135 | .035 | 7 |
BXA095902B | BXB095902B | 9 | 13 | 59 | 135 | .035 | 7 |
BXA097902B | BXB097902B | 9 | 13 | 79 | 135 | .035 | 7 |
BXA102902B | Unchanged | 10 | 13 | 29 | 135 | .035 | 8 |
BXA103902B | Unchanged | 10 | 13 | 39 | 135 | .035 | 8 |
BXA105902B | Unchanged | 10 | 13 | 59 | 135 | .035 | 8 |
BXA107902B | Unchanged | 10 | 13 | 79 | 135 | .035 | 8 |
BXA112902B | Unchanged | 11 | 16 | 29 | 135 | .035 | 8 |
BXA113902B | Unchanged | 11 | 16 | 39 | 135 | .035 | 8 |
BXA115902B | Unchanged | 11 | 16 | 59 | 135 | .035 | 8 |
BXA117902B | Unchanged | 11 | 16 | 79 | 135 | .035 | 8 |
BXAL082902B | BXBL082902B | 8 | 16 | 29 | 135 | .035 | 7 |
BXAL083902B | BXBL083902B | 8 | 16 | 39 | 135 | .035 | 7 |
BXAL085902B | BXBL085902B | 8 | 16 | 59 | 135 | .035 | 8 |
BXAL087902B | BXBL087902B | 8 | 16 | 79 | 135 | .035 | 8 |
a Secondary balloon required to post-dilate the stent beyond its nominal deployed diameter (secondary balloon not included).
b Based on idealized in-vitro conditions and provided to be used as a general guide.

Refer to Instructions for Use at eifu.goremedical.com for a complete description of all applicable indications, warnings, precautions and contraindications for the markets where this product is available. RXOnly
INDICATIONS FOR USE IN THE US: The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is indicated for the treatment of de novo or restenotic lesions found in iliac arteries with reference vessel diameters ranging from 5 mm - 13 mm and lesion lengths up to 110 mm, including lesions at the aortic bifurcation. The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is indicated to maintain visceral artery perfusion as a bridging stent in:
- fenestrated endovascular aortic aneurysm repair with 6-8 mm diameter fenestrations
- branched endovascular aortic aneurysm repair with 6-8 mm diameter branches (e.g. portals, cuffs, or directional branches) that are at least 10 mm in length
Bridging stent use is limited to aortic endovascular graft systems wherein safety and effectiveness has been demonstrated.
CONTRAINDICATIONS: Do not use the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis in patients with known hypersensitivity to heparin, including those patients who have had a previous incident of Heparin-Induced Thrombocytopenia (HIT) type II. Patients with known sensitivities or allergies to the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis materials including expanded polytetrafluoroethylene (ePTFE), fluorinated ethylene propylene (FEP), stainless steel, and heparin.
The GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis is not authorized for use with thoracoabdominal and pararenal branched devices indicated with the GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis as a branch component in Canada.